IREM-HYDRO-pelton-TPS_1-removebg-preview

PELTON TPS TURBINES

ECOWATT HYDRO TPA 3-550 KW
GENERAL CHARACTERISTICS
Certifications 2006\42\CE (Machinery Directive);
2014\35\EU (Low voltage);
2014\30\EU (EMC)
Power range 3 – 550 kW
Jump range 30-550m
Flow rate range 2-400 l/s
Number of jets 6
Flow rate adjustment Electrically operated on/off valves for automatic regulation
Generator synchronous, brushless, self-excited, three-phase (possible connection of single-phase loads)
Generator insulation/overtemperature class H/B
Generator bearings lubricated for life / with grease nipple
Frequency 50-60Hz
Tensions 230/400V – 277/480V
Degree of protection IP23
Mechanical components in contact with water in stainless steel

IREM-HYDRO-acquedotti

PELTON TPA TURBINE AQUEDUCT

PELTON TPA TURBINE AQUEDUCT
ECOWATT HYDRO TPA AQUEDUCT 3-750 KW
GENERAL CHARACTERISTICS
Certifications 2006\42\CE (Machinery Directive);
2014\35\EU (Low voltage);
2014\30\EU (EMC);
DM 174/2004-Italy (Installations on aqueducts);
ACS-France (Attestation de Conformité Sanitaire)
Power range 3 – 750 kW
Jump range 30-550m
Flow rate range 2-400 l/s
Number of jets 6
Flow rate adjustment Electrically operated on/off valves for automatic regulation
Generator asynchronous, squirrel cage, high efficiency
Generator insulation/overtemperature class F/B
Generator bearings lubricated for life / with grease nipple
Generator winding temperature sensor N°3 PTC in series
Frequency 50-60Hz
Tensions 230/400V – 277/480V, three-phase
Degree of protection IP23 (generator protection degree IP55)
Rotation speed sensor proximity 1 signal/turn
Components in contact with water certified DM 174/2004 (Italy) – ACS (France)

IREM-HYDRO-pelton-TPA_1

PELTON TPA TURBINE

PELTON TPA TURBINE
ECOWATT HYDRO TPA 3-750 KW
GENERAL CHARACTERISTICS
Certifications 2006\42\CE (Machinery Directive);
2014\35\EU (Low voltage);
2014\30\EU (EMC)
Power range 3 – 750 kW
Jump range 30-550m
Flow rate range 2-400 l/s
Number of jets 6
Flow rate adjustment Electrically operated on/off valves for automatic regulation
Generator asynchronous, squirrel cage, high efficiency
Generator insulation/overtemperature class F/B
Generator bearings lubricated for life / with grease nipple
Generator winding temperature sensor N°3 PTC in series
Frequency 50-60Hz
Tensions 230/400V – 277/480V, three-phase
Degree of protection IP23 (generator protection degree IP55)
Rotation speed sensor proximity 1 signal/turn
Mechanical components in contact with water in stainless steel

turbina-bank-tba-acquedotto

TURBINE BANKI TBA AQUEDUCT

TURBINE BANKI TBA AQUEDUCT
ECOWATT HYDRO TBA AQUEDUCT 3-250 KW
GENERAL CHARACTERISTICS
Certifications 2006\42\CE (Machinery Directive);
2014\35\EU (Low voltage);
2014\30\EU (EMC);
DM 174/2004-Italy (Installations on aqueducts);
ACS-France (Attestation de Conformité Sanitaire)
Power range 3 – 250 kW
Jump range 5-50m
Flow rate range 20-1500 l/s
Flow rate adjustment adjustment plate operated by electric servomotor for automatic adjustment
Generator asynchronous, squirrel cage, high efficiency
Generator insulation/overtemperature class F/B
Generator bearings lubricated for life / with grease nipple
Generator winding temperature sensor N°3 PTC in series
Frequency 50-60Hz
Tensions 230/400V – 277/480V, three-phase
Degree of protection IP23 (generator protection degree IP55)
Rotation speed sensor proximity 1 signal/turn
Components in contact with water certified DM 174/2004 (Italy) – ACS (France)

IREM-HYDRO-banki-TBA_1

TURBINE BANKI TBA

TURBINE BANKI TBA
ECOWATT HYDRO TBA 3-250 KW
GENERAL CHARACTERISTICS
Certifications 2006\42\CE (Machinery Directive);
2014\35\EU (Low voltage);
2014\30\EU (EMC)
Power range 3 – 250 kW
Jump range 5-50 m
Flow rate range 20-1500 l/s
Flow rate adjustment adjustment plate operated by electric servomotor for automatic adjustment
Generator asynchronous, squirrel cage, high efficiency
Generator insulation/overtemperature class F/B
Generator bearings lubricated for life / with grease nipple
Generator winding temperature sensor N°3 PTC in series
Frequency 50-60Hz
Tensions 230/400V – 277/480V, three-phase
Degree of protection IP23 (generator protection degree IP55)
Rotation speed sensor proximity 1 signal/turn
Mechanical components in contact with water in stainless steel

IREM-HYDRO-banki-TBS_1

TBS BANKI TURBINE

TBS BANKI TURBINE
ECOWATT HYDRO TBS 3-250 KW
GENERAL CHARACTERISTICS
Certifications 2006\42\CE (Machinery Directive);
2014\35\EU (Low voltage);
2014\30\EU (EMC)
Power range 3 – 250 kW
Jump range 5-50 m
Flow rate range 20-1500 l/s
Flow rate adjustment adjustment plate operated by electric servomotor for automatic adjustment
Generator synchronous, brushless, self-excited, three-phase (possible connection of single-phase loads)
Generator insulation/overtemperature class H/B
Generator bearings lubricated for life / with grease nipple
Temperature sensor
Frequency 50-60Hz
Tensions 230/400V – 277/480V, three-phase
Degree of protection IP23
Mechanical components in contact with water in stainless steel