TD_MIXVENT_product1-removebg-preview

TD-MIXVENT

Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 2000 models) or with metal casing steel finished in a tough epoxy-polyester paint coating (for models 4000 and 6000).
The unique design of the support bracket allows the motor and impeller assembly to be fitted or removed without dismantling the adjacent ducting.

Motors
Models 160-2000:
Class B, with ball bearings and safety thermal overload protection. IP44.
Direct 2 or 3 speed connection and also suitable for voltage speed control.
Electrical supply:
Single phase 230V-50Hz. (models from 160 to 350)
Single phase 230V-50/60Hz. (models from 500 to 2000)

Models 4000 and 6000:
Class F, with ball bearings and safety thermal overload protection. IP54.
Suitable for voltage speed control.
Electrical supply:
Single phase 230V-50/60Hz.
Three phase 400V-50/60Hz (model 4000) or 400V-50Hz (model 6000)

Additional information
Three phase models adjustable by inverter control.

0
TD_ECOWATT_product1-removebg-preview

TD-ECOWATT

Range of low profile mixed flow fans with ball bearings and brushless DC motors, of high efficiency and low consumption. Manufactured in plastic (models 160 to 800) or in steel (models 1300 and 2000), removable fan body, and rated as standard 90/260V- 50/60Hz for models 160 to 800 and 230V/50-60Hz for models 1300 and 2000. Fan speed 100% adjustable with the potentiometer placed in the connection box (excepted TD-160/100 ECOWATT) or with an external control type REB-ECOWATT. Analogue input with terminals in the terminal box to control the fan with 0-10V input signal.
Working temperatures from -20ºC to +40ºC.
Suitable for any kind of ventilation application where the noise level of the ventilation system is of particular importance and, due to continuous operation, a significant energy saving is desirable. It is also suitable for applications that require a Demand Controlled Ventilation System involving the use of other sensors or controls.

0
TD_CALOR_FILTER_mixfilter_product1-removebg-preview

MIXVENT FILTER

TD-MIXVENT + FILTER BOX MFL-G4

The MIXVENT HEATING system consists on a MFL filtration box installed on the inlet side of the TD-MIXVENT fan and are used when the installation requires supplying filtered clean air. MFL filtration boxes are of EU4 grade filtration and are designed for direct connection with standard circular ducting.

Attributes

  • The MFL filtration boxes are supplied with a cover easily removable to replace the filter.
0
JETLINE_150_ECOWATT_lateral-removebg-preview

JETLINE ECOWATT

Range of in-line fans for circular ducts, designed for high aerodynamic performances with a very compact profiles and very low sound levels.

Low profile compact casing manufactured from galvanised sheet steel. The terminal box and the mounting

  • Terminal box
    Built-in, IP65 terminal box that does not add to the overall height dimensions.
  • Airtight joints
    Rubber gaskets for a more airtight joint with the installation’s ducts.
  • High performance Impeller
    New impeller geometry for reduced sound levels and to offer high performance.
  • Mounting bracket
    Strong mounting bracket supplied with the fan.
  • Two mounting positions for support
    The product can be mounted in two different positions by changing the position of the support’s anchoring.
0
JETLINE_150_product01-removebg-preview

JETLINE

Range of in-line fans for circular ducts, designed for high aerodynamic performances with a very compact profiles and very low sound levels.The range comprises 7 diameters and covers a flow range from 260 to 1080 m3/h.
Low profile compact casing manufactured from galvanised sheet steel. The terminal box and the mounting bracket do not increase the product’s profile.Optimised design of the impeller, guide vane and outlet diffuser, manufactured from injection moulded plastic, to increase performance and lower the sound level.
Airtight joint between the galvanised steel casing and the plastic guide vane to avoid air leaks. Rubber gaskets on the flanges to improve airtightness with the ducts. Silent block between the motor and the holder to reduce the motor’s vibrations and lower the sound level of the installation, even in terms of speed regulation.

JETLINE models with 220-240V 50/60Hz motor
Fitted with an external rotor single-phase AC motor:

  • Class F, IP 44
  • Speed controllable by voltage.
  • Thermal protection with manual reset.
  • Working temperature: -20/60 ºC
  • 0
IREM-HYDRO-acquedotti

PELTON TPA TURBINE AQUEDUCT

PELTON TPA TURBINE AQUEDUCT
ECOWATT HYDRO TPA AQUEDUCT 3-750 KW
GENERAL CHARACTERISTICS
Certifications 2006\42\CE (Machinery Directive);
2014\35\EU (Low voltage);
2014\30\EU (EMC);
DM 174/2004-Italy (Installations on aqueducts);
ACS-France (Attestation de Conformité Sanitaire)
Power range 3 – 750 kW
Jump range 30-550m
Flow rate range 2-400 l/s
Number of jets 6
Flow rate adjustment Electrically operated on/off valves for automatic regulation
Generator asynchronous, squirrel cage, high efficiency
Generator insulation/overtemperature class F/B
Generator bearings lubricated for life / with grease nipple
Generator winding temperature sensor N°3 PTC in series
Frequency 50-60Hz
Tensions 230/400V – 277/480V, three-phase
Degree of protection IP23 (generator protection degree IP55)
Rotation speed sensor proximity 1 signal/turn
Components in contact with water certified DM 174/2004 (Italy) – ACS (France)

0
IREM-HYDRO-pelton-TPA_1

PELTON TPA TURBINE

PELTON TPA TURBINE
ECOWATT HYDRO TPA 3-750 KW
GENERAL CHARACTERISTICS
Certifications 2006\42\CE (Machinery Directive);
2014\35\EU (Low voltage);
2014\30\EU (EMC)
Power range 3 – 750 kW
Jump range 30-550m
Flow rate range 2-400 l/s
Number of jets 6
Flow rate adjustment Electrically operated on/off valves for automatic regulation
Generator asynchronous, squirrel cage, high efficiency
Generator insulation/overtemperature class F/B
Generator bearings lubricated for life / with grease nipple
Generator winding temperature sensor N°3 PTC in series
Frequency 50-60Hz
Tensions 230/400V – 277/480V, three-phase
Degree of protection IP23 (generator protection degree IP55)
Rotation speed sensor proximity 1 signal/turn
Mechanical components in contact with water in stainless steel

0
turbina-bank-tba-acquedotto

TURBINE BANKI TBA AQUEDUCT

TURBINE BANKI TBA AQUEDUCT
ECOWATT HYDRO TBA AQUEDUCT 3-250 KW
GENERAL CHARACTERISTICS
Certifications 2006\42\CE (Machinery Directive);
2014\35\EU (Low voltage);
2014\30\EU (EMC);
DM 174/2004-Italy (Installations on aqueducts);
ACS-France (Attestation de Conformité Sanitaire)
Power range 3 – 250 kW
Jump range 5-50m
Flow rate range 20-1500 l/s
Flow rate adjustment adjustment plate operated by electric servomotor for automatic adjustment
Generator asynchronous, squirrel cage, high efficiency
Generator insulation/overtemperature class F/B
Generator bearings lubricated for life / with grease nipple
Generator winding temperature sensor N°3 PTC in series
Frequency 50-60Hz
Tensions 230/400V – 277/480V, three-phase
Degree of protection IP23 (generator protection degree IP55)
Rotation speed sensor proximity 1 signal/turn
Components in contact with water certified DM 174/2004 (Italy) – ACS (France)

0
IREM-HYDRO-banki-TBA_1

TURBINE BANKI TBA

TURBINE BANKI TBA
ECOWATT HYDRO TBA 3-250 KW
GENERAL CHARACTERISTICS
Certifications 2006\42\CE (Machinery Directive);
2014\35\EU (Low voltage);
2014\30\EU (EMC)
Power range 3 – 250 kW
Jump range 5-50 m
Flow rate range 20-1500 l/s
Flow rate adjustment adjustment plate operated by electric servomotor for automatic adjustment
Generator asynchronous, squirrel cage, high efficiency
Generator insulation/overtemperature class F/B
Generator bearings lubricated for life / with grease nipple
Generator winding temperature sensor N°3 PTC in series
Frequency 50-60Hz
Tensions 230/400V – 277/480V, three-phase
Degree of protection IP23 (generator protection degree IP55)
Rotation speed sensor proximity 1 signal/turn
Mechanical components in contact with water in stainless steel

0
IREM-HYDRO-banki-TBS_1

TBS BANKI TURBINE

TBS BANKI TURBINE
ECOWATT HYDRO TBS 3-250 KW
GENERAL CHARACTERISTICS
Certifications 2006\42\CE (Machinery Directive);
2014\35\EU (Low voltage);
2014\30\EU (EMC)
Power range 3 – 250 kW
Jump range 5-50 m
Flow rate range 20-1500 l/s
Flow rate adjustment adjustment plate operated by electric servomotor for automatic adjustment
Generator synchronous, brushless, self-excited, three-phase (possible connection of single-phase loads)
Generator insulation/overtemperature class H/B
Generator bearings lubricated for life / with grease nipple
Temperature sensor
Frequency 50-60Hz
Tensions 230/400V – 277/480V, three-phase
Degree of protection IP23
Mechanical components in contact with water in stainless steel